Publications

Davis TS, Wark HAC, Hutchinson DT, Warren DJ, O’Neill III K, Scheinblum T, Clark GA, Normann RA, Greger B, Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves. Journal of Neural Engineering 2016

Smith EH, Liou J, Davis T, Merricks EM, Kellis SS, Weiss SA, Greger B, House PA, McKhann II GM, Goodman RR, Emerson RG, Bateman LM, Trevelyan AJ, Schevon CA, The ictal wavefront is the spatiotemporal source of discharges during spontaneous human seizures. Nature Communications 2016

ChristieBP, Ashmont KR, House PA, Greger B, Approaches to a cortical vision prosthesis: implications of electrode size and placement. Journal of Neural Engineering 2015

Kellis SS, Sorenson L, Darvas F, Sayres C, Brown R, House PA, Ojemann J, Greger B, Multi-scale analysis of neural activity in humans: implications for micro-scale electrocorticography. Clinical Neurophysiology 2015

Seyedhosseini M, Shushruth S, Davis T, Ichida JM, Greger B, Angelucci A, Tasdizen T, Informative features of local field potential signals in primary visual cortex during natural image stimulation. Journal of Neurophysiology 2015

Fernández E, Greger B, House PA, Aranda I, Botella C, Albisua J, Soto-Sánchez C, Alfaro A, Normann RA, Acute human brain responses to intracortical microelectrode arrays: challenges and future prospects. Frontiers in Neuroengineering 2014

Stacey WC, Kellis SS, Greger B, Butson C, Patel PR, Assaf T, Mihaylova T, Glynn S, Unreliable interpretation of EEG recorded with microelectrodes. Epilepsia 2013

Smith E, Duede S, Hanrahan S, Davis T, House P, Greger B. Seeing is believing: neural representations of visual stimuli in human auditory cortex correlate with illusory auditory perceptions. PLoS One. 2013

Hanrahan SJ, Greger B, Parker RA, Ogura T, Obara S, Egan T, House PA, The effects of propofol on local field potential spectra, action potential firing rate, and their temporal relationship in humans and felines. Frontiers of Human Neuroscience 2013

Smith E, Kellis SS, House PA, Greger B, Decoding stimulus identity from action potentials and local field potentials along the ventral auditory stream in the awake primate: implications for cortical neural prostheses. Journal of Neural Engineering 2013

Davis TS, Parker RA, House PA, Bagley E, Wendelken S, Normann RA, Greger B, Spatio-temporal characteristics of V1 microstimulation during long-term chronic implantation of a microelectrode array in a behaving macaque. Journal of Neural Engineering 2012

Dehghani N, Hatsopoulos NG, Haga ZD, Parker RA, Greger B, Halgren E, Cash SS, Destexhe A, Avalanche analysis from multi-electrode ensemble recordings in cat, monkey and human cerebral cortex during wakefulness and sleep. Frontiers in Fractal Physiology 2012

Egan J, Baker J, House PA, Greger B, Decoding dexterous finger movements in a neural prosthesis model approaching real-world conditions. IEEE Transactions on Neural Systems and Rehabilitation 2012

Stacey WC, Kellis SS, Patil P, Greger B, Butson C, Signal distortion from microelectrodes in clinical EEG acquisitions systems. Journal of Neural Engineering 2012

Parker RA, Davis TS, House PA, Normann RA, Greger B, The functional consequences of chronic, physiologically effective intracortical micro-stimulation. Progress in Brain Research 2011

Torab K, Davis TS, Warren DJ, House PA, Normann RA, Greger B, Multiple factors may influence the performance of a visual prosthesis based on intracortical microstimulation: nonhuman primate behavioural experimentation. Journal of Neural Engineering 2011 Jun;8(3):035001. (Selected for JNE Highlights 2011)

Kellis SS, Miller K, Thomson KE, Brown R, House PA, Greger B, Decoding spoken words using local field potentials recorded from the cortical surface. Journal of  Neural Engineering 2010 Oct;7(5) (Selected for JNE Highlights 2010)

Baker JJ, Scheme E, Englehart K, Hutchinson DT, Greger B, Decoding individuated finger flexions wirelessly with implantable myoelectric sensors. IEEE Transactions on Neural Systems and Rehabilitation, 2010 Aug;18(4):424-32

Kellis SS, House PA, Thomson KE, Brown R, Greger B, Human neocortical electrical activity recorded on non-penetrating microwire arrays: applicability for neuroprostheses. Neurosurgical Focus 2009

Davis TS, Torab K, House PA, Greger B, A minimally invasive approach to long-term head fixation in behaving non-human primates. Journal of Neuroscience Methods 2009 Jun 30;181(1):106-10.

Harrison RR, Kier RF, Chestek CA, Gilja V, Nuyujukian P, Ryu SI, Greger B, Solzbacher F, Shenoy KV, Wireless neural recording with single low-power integrated circuit. IEEE Trans. Neural Sys & Rehab. Eng. 2009 Aug;17(4):322-9

Lehmkuhle MJ, Thomson KE, Scheerlinck P, Pouliot W, Greger B, Dudek FE, A simple quantitative method for analyzing electrographic status epilepticus in rats. Journal of Neurophysiology 2009 Mar;101(3):1660-70

Hakimian S, Norris SA, Greger B, Keating JG, Anderson CH, Thach WT, Time and frequency characteristics of purkinje cell complex spikes in the awake monkey performing a non-periodic task. Journal of Neurophysiology 2008 Aug;100(2):1032-40.

Greger B, Kateb B, Gruen P, Patterson PH,  A chronically implantable, hybrid cannula-electrode device for assessing the effects of molecules on electrophysiological signals in freely behaving animals. Journal of Neuroscience Methods 163(2):321-5, 2007

Harrison RR, Watkins PT, Kier RJ, Lovejoy RO, Black DJ, Greger B, Solzbacher F, A low-power integrated circuit for a wireless 100-electrode neural recording system.  IEEE Journal of Solid-State Circuits 42:1, 2007

Greger B, Norris SA, Simple spike firing in posterior lateral cerebellar cortex of Macaque Mulatta was correlated with success-failure during a visually guided reaching task. Experimental Brain Research 167(4):660-5, 2005

Cham J, Branchaud EA, Nenadic Z, Greger B, Andersen RA, Burdick JW,  A semi-chronic motorized microdrive and control algorithm for autonomously isolating and maintaining optimal extracellular action potentials. Journal of Neurophysiology 93:570-80, 2005

Musallam S, Corneil B, Greger B, Scherberger H, Andersen RA, Use of cognitive control signals in decoding movement goals for neuroprosthetic development.  Science 304(5681) 258-62, 2004

Norris SA, Greger B, Hathaway EN, Thach WT, Purkinje cell spike firing in the posterolateral cerebellum: correlation with visual stimulus, oculomotor response, and error feedback. Journal of Neurophysiology 92:1867-79, 2004

Greger B, Norris SA, Thach WT, Spike firing in the lateral cerebellar cortex correlated with movement and motor parameters irrespective of the effector limb. Journal of Neurophysiology 91:576-582, 2004

Martin TA, Norris SA, Greger B, Thach WT, Dynamic coordination of body parts during prism throwing. Journal of Neurophysiology 88: 1685 – 94, 2002

Martin TA, Greger B, Norris SA, Thach WT, Throwing accuracy in the vertical direction during prism adaptation: not simply timing of ball release. Journal of Neurophysiology 85:2298-2302, 2001

Norris SA, Greger B, Martin TA, Thach WT, Prism adaptation of reaching is dependent on the type of visual feedback of hand and target position. Brain Research, 905(1-2):207-19, 2001

Li CP, Olavarria JF, Greger B, Occipital cortico-pyramidal projection in hypothyroid rats. Brain Research:  Developmental Brain Research   89(2):227-234, 1995